Menu
Your Cart

Kotel na tuhá paliva Prity NS26, 28.9kW

Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
DORUČENÍ ZDARMA
Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
Kotel na tuhá paliva Prity NS26, 28.9kW | Kotle na tuhá paliva | Dřevo |
Kotel na tuhá paliva Prity NS26, 28.9kW

Kotel na dřevo řady NS. Středně velký model na dřevo pro ústřední vytápění.

  • Stock: Skladem
  • Značka: Prity
  • SKU: 08.438.015
38,311.12Kč
Včetně DPH
Osvobozeno od daně: 31,925.94Kč
ODHADOVANÉ DORUČENÍ
24.Feb.2025
DHL Schenker
Viz Zásady Dopravy

Vrácení zdarma
60 dníProhlednout detaily

Přijímáme platby
    Prohlednout detaily

Kotel je určen pro umístění v přízemní místnosti nebo suterénu, kde je snadné nakládat dřevo a dřevěné brikety.

Jejím účelem je ohřev vody pro lokální ústřední vytápění a ohřev teplé užitkové vody.

Hlavní vlastnosti kotle na dřevo:

  • Tělo z ocelového plechu o tloušťce 2 mm
  • Vrchní deska z ocelového plechu o tloušťce 3-4 mm
  • Hlavní částí kotle je výměník tepla. Je vyrobena ze svařovaného plechu. Spodní část je spalovací komora.
  • Zásuvka na popel je umístěna pod spalovací komorou. Shromažďuje zbytky z procesu hoření a umožňuje snadnou údržbu a čištění jednotky.
  • Vstup studené vody je umístěn nahoře a výstup teplé vody - na zadní straně. Oba jsou závitové a slouží k připojení kotle k systému ústředního vytápění.
  • Komínová trubka je na horní části kotle a slouží k odvodu spalin.
  • Ocelový výměník tepla má izolaci z minerální vlny, která snižuje tepelné ztráty do okolí.
  • Vnější ozdobné strany jsou vyrobeny z plechu a opatřeny práškovou barvou.
  • Pro regulaci komínového tahu je na kouřovodu umístěna ruční klapka.
  • Ruční klapka pro primární vzduch.
  • Regulace vzduchu pomocí kapilárního termostatu plynule reguluje teplotu teplé vody od 50°C do 90°C, čímž zvyšuje výkon a hospodárnost spalovacího procesu.

Dosažení požadovaného tepelného výkonu závisí na:

  • zvolené palivo s potřebnou výhřevností a vlhkostí
  • its subsequent kindling and refueling
  • the regulation of the primary and the secondary air
  • the regulation of the draught
  • the organizing of effective air heat exchange, etc.

Installation instructions

  • Ask for an advice from a professional before connecting the boiler to the chimney and the central heating system.
  • The boiler must be placed on a horizontal, nonflammable floor. To protect the floor, a nonflammable pad can be placed below the wood boiler. If a pad is used, it should stick out at least 50 cm in front of the boiler and 30cm on each side.
  • In the immediate vicinity of the boiler (within 80cm of each side) no objects should be placed if they are flammable or can be damaged from the heat.
  • All elements connecting the boiler to the chimney must be firmly fixed, but not in a way that places them inside the passage section of the chimney.
  • The chimney pipes should be the same diameter as the one on the boiler.
  • It is recommended to connect the boiler to a separate chimney. Other heating bodies can be connected to the same chimney only if it is designed for that purpose.
  • The flow of fresh air inside the boiler must be at least 4 m³/h for every kilowatt of heating output. If needed, air can be supplied from another room or from outside.
  • The burning process of the boiler must not be deprived of air when gravity or forced aspirations are at work, because in such cases the burning is incomplete and/or flue gas can be returned in the room.
  • The boiler should be connected to a central heating systems with suitable fittings and fixtures, according to a prepared beforehand heating project.

WARNING!

 - Nesmí se odpalovat, pokud není připojen k radiátorům / konvektorům s ventilátorem. Spalování dřeva bez vody v kotli způsobí jeho prasknutí a následnou ztrátu záruky. 

Doporučení:

- Doporučujeme instalaci provést v systému otevřeného typu. Při zapojení do systému s uzavřeným okruhem musí být plně chráněn bezpečnostními ventily pro teplotu a tlak do 1,5 bar.

- Všechny prvky instalace musí být chráněny před mrazem. Při instalaci s nuceným oběhem doporučujeme čerpadlo zálohovat UPS.

- V každé instalaci s měděnými částmi by měl být kotel chráněn proti korozivní elektrolýze pomocí hořčíkové obětní anody nebo podobného ochranného systému

 

Characteristics
Hmotnost (kg) 165.0000
Země výroby Bulharsko
Rozměr hloubka (mm) 510
Rozměr šířka (mm) 570
Rozměr výška (mm) 1150
Certifikace Ekodesign
Jmenovitý tepelný výkon (kW) 28.9
Třída energetické účinnosti A
Spalinový odvod (mm) 130
Umístění výfuku Horní strana
Ovládací panel Ne
Nucená ventilace spalování Ne
Tepelný výkon (kW) 28.9
Doporučené palivo Dřevo s vlhkostí do 20 %
Účinnost (%) 77.5
Jmenovitý výkon ohřevu vody (kW) 26.3
Stavební materiál Ocel
Spotřeba paliva během topného období 4.2 kg/h
Výkon prostorového vytápění (kW) 2.6
Chladný vstup vody 1"
Horký výstup vody 1"
Kontejner na popel a saze Ano
Maximální teplota spalin (°C) 271
Měření CO při 13% kyslíku při nominálním výkonu (sníženo) [%] 1212.5 mg/Nm³
Emise (g/s) 21,4
Chladící okruh Ne
Maximální systémový tlak (bar) 1.5
Regulátor tahu termoregulovaný Ano
Rozměry spalovací komory (výška, šířka, hloubka), mm 515 x 430 x 385
Doporučený typ systému Otevřený
Klapka komínu Ano
Možnost instalace peletového hořáku Ne
Type File Information
Declaration of performance_NS26.pdf 2.78MB
Energy efficiency label_NS26 .pdf 89.6KB